ANTERION for cataract surgery planning
Transform your cataract surgery routine with ANTERION
The ANTERION® combines biometry with corneal topography and tomography, anterior chamber metrics, and high-resolution OCT imaging in a single, small, workflow efficient device. The ANTERION is a true multi-modality platform, ideally suited to high-throughput cataract clinics and surgical hubs.
Capture all the biometric data you need
The ANTERION Cataract App uses high-resolution swept-source OCT to generate the most important biometry measurements for cataract surgery planning: corneal analysis, anterior chamber depth, lens thickness, and axial length. ANTERION offers both spheric and toric IOL calculation, a comprehensive range of established IOL formulas, and provides the data to calculate the most suitable IOL for your patient, without changing devices.
Cornea analysis customised to your preferences
Add the ANTERION Cornea App and receive a comprehensive set of measurements for evaluation of the corneal geometry of your patients. Detailed topographic and tomographic data, conveniently accessible on the same platform, reduces the risk of refractive surprises during your cataract surgery planning. Visualise all relevant information using customisable templates, presets, and reports.
Measurements you can trust
Viewing the OCT images that generate the data helps you to confirm your measurements. Detect hidden anomalies, monitor change, compare pre- and post-operative metrics, and visualise surgical results. Several clinical studies provide evidence that ANTERION measurements are very repeatable1 and have high agreement with other devices2, making it easy to integrate ANTERION data into your existing workflows and calculation methods.
Optimise your clinical workflow
With the ANTERION Cataract and Cornea Apps, all this data is at your fingertips with as few as one quick click of the joystick button. Save time and space by examining the patient at one device and efficiently work through patient backlogs.
For more valuable information about our products, educational offerings, learning materials and events
Subscribe to our Newsletter orContact us
1. ANTERION Repeatability Studies:
Shetty N, Kaweri L, Koshy A, Shetty R, Nuijts R, Roy AS. Repeatability of biometry measured by IOLMaster 700, Lenstar LS 900 and Anterion, and its impact on predicted intraocular lens power. J Cataract Refract Surg. 2020 Nov 23. doi: 10.1097/j.jcrs.0000000000000494
Schiano-Lomoriello D, Hoffer KJ, Abicca I, Savini G. Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices. Sci Rep. 2021 Jan 13;11(1):983. https://doi.org/10.1038/s41598-020-79674-4
Tañá-Rivero P, Aguilar-Córcoles S, Ruiz-Mesa R, Montés-Micó R. Repeatability of whole-cornea measurements using a new swept-source optical coherence tomographer. Eur J Ophthalmol. 2021 Jul;31(4):1709-1719. doi: 10.1177/1120672120944022
2. ANTERION Device Comparison Studies:
Fişuş AD, Hirnschall ND, Findl O. Comparison of 2 swept-source optical coherence tomography-based biometry devices. J Cataract Refract Surg. 2021 Jan 1;47(1):87-92. doi: 10.1097/j.jcrs.0000000000000373
Shetty N, Kaweri L, Koshy A, Shetty R, Nuijts R, Roy AS. Repeatability of biometry measured by IOLMaster 700, Lenstar LS 900 and Anterion, and its impact on predicted intraocular lens power. J Cataract Refract Surg. 2020 Nov 23. doi: 10.1097/j.jcrs.0000000000000494
Herber R, Lenk J, Pillunat LE, Raiskup F. Agreement and repeatability of corneal tomography in healthy eyes using a novel Swept-Source optical coherence tomographer, a rotating Scheimpflug camera and a dual Scheimpflug-Placido system. J Cataract Refract Surg. 2021 Jun 28.doi: 10.1097/j.jcrs.0000000000000734Abstract